BioMaster™ PLUS Reverse Osmosis System is a unique unit that combines sediment filtration, heavy metal filtration, carbon filtration, and RO technology with UV disinfection for the most comprehensive and affordable drinking water treatment available to the home owner.

For pennies a day, the BioMaster™PLUS will deliver better than bottled water quality.  A properly maintained BioMaster™ PLUS drinking water system means you will never have to worry again about the quality of your water supply.

The BioMaster™ Plus is much more than an RO system. It has been designed to work on water that may have chemical and/or bacterial contamination. The carbon filtration modules will remove, or significantly reduce, over 50 chemical substances that the EPA has deemed potential carcinogens.

 

FEATURES:

 

  • Sediment filtration to remove particulate matter (grit, sand, sludge, silt, etc).
  • A special heavy metal pre-filter cartridge will extend the life of the RO membrane and remove lead, copper, zinc, etc).
  • Pre- and post-carbon filtration for the removal of chlorine, taste, odor, color, pesticides, and a whole list of chemical compounds deemed unhealthy by the EPA (see list below).
  • A reverse osmosis membrane for ultrafine (molecular) filtration. Primary agents filtered are sodium, nitrates, lead, flouride, cryptosporidium, cysts, iron, copper, mercury, and arsenic.  The RO element in the  BioMaster™ will remove 93% to 99+% of these and other compounds (see list below).
  • An ultraviolet disinfecting chamber sterilizes viruses, bacteria, mold, algae, and other harmful micro-organisms.
  • Large 4 gallon water reservoir.
  • All hardware necessary for installation.

 

 

 

 

 

This PLUS model includes a precision digital dual-channel TDS meter to monitor your system's performance, and an upgraded brushed-nickle faucet.

 

 

 

Performance specifications for a properly installed and maintained Biomaster™ system include:

The carbon filtration modules will remove, or significantly reduce, over 50 chemical substances that the EPA has deemed potential carcinogens. They include:

Adipates(diethylhexyl) Chromium (+3) Endrin PCB’s
Alachlor Chrysene (PAH) Ethylbenzene Sediment
Aldicarb Dalapon Ethelene dibromide(EDB) Simarzine
Aldicarb sulfone Di (2-ethylhexl) adipate Glyphosate Styrene
Aldicarb sulfoxide Dibenz (a,h) antracene Heptachlor 3,7,8-TCDD (dioxin)
Atrazine Dibromochloropropane Heptachlor epoxide 2,4-D 2,4,5-TP (silvex)
Benz (a) anthracine (PAH) Dichlorobenzene (meta-) Hextachlorobenzene TCB’s
Benzene Dichlorobenzene (ortho) Hextachlorocyclopentadiene TCE’s
Benzo (a) pyrene (PAH) Dichlorobenzene (para-) Indo (1,2,3-c,d) pyrene (PAH) Tetrachloroethylene
Benzo (b) floranthene (PAH) Dichloroethane (1,2-) Lidane Thallium
Benzo (k) floranthene (PAH) Dichloroethylene (1,1-) Mercury (organic complexes) THM’s
Beryllium Dichloroethylene (cis-1,2-) Methoxychlor Toulene
Butyl benzyl phthalate (PAE) Dichloroethylene (trans-1,2) Monochlorobenzene Toxaphene
Cadmium Dichloropropane Organic color Vinyl chloride
Carbofuran Diethylhexyl phthalate (PAE) Organics Xylenes
Carbon tetrachloride Dinoseb Oxymal
Chlordane Diquat Pentachlorophenal
Chlorine Endothall Picloram

 

The RO membrane module will reject the following substances from tap water:

Arsenic 94-96% Copper 98-99% Mercury 96-98% Silicate 95-97%
Barium 96-98% Cyanide 86-95% Nickel 98-99% Silver 95-97%
Bicarbonate 95-96% Flouride 94-96% Nitrate 90-96% Sodium 87-98%
Boron 60-70% Hardness 95-98% Phosphate 96-99% Strontium 96-98%
Bromide 93-96% Iron 95-98% Potassium 87-97% Sulfate 98-99%
Cadmium 96-98% Lead 96-98% Pyrogen 98-99% Zinc 98-99%
Calcium 94-97% Magnesium 96-98% Selenium 96-98%
Chloride 87-95% Manganese 98-99% Silica 85-90%

The RO membrane module will also aid in the removal of color, asbestos, and cysts such as giardia and cryptosporidium.

 

The UV sterilization chamber is where any viruses, bacteria, mold, and other living microorganisms are bombarded with special, intense light of a specific wavelength. The UV light penetrates the wall of the organisms and attacks their DNA structure leaving the organism unable to reproduce (or "dead"). UV technology is recognized by the EPA as one of four approved methods of sterilizing water, and is preferable over the other three methods (chlorine, iodine, and distillation) due to the cost of treatment and effectiveness (UV works almost instantaneously, leaving no residuals or chemicals in the water). The BioMaster™ UV module operates for a full year at  a dosage of 30,000 microwatt seconds/cm². As a point of reference, the table below is a list of common bacteria and viruses, and the dosage required to render them harmless.

BACTERIA MOLD SPORES
Bacillus anthacis 8,700 Mucor racemosus A 35,200
B. Megaatherium sp. (veg.) 2,500 Mucor racemosus B 35,200
B. Megaatherium sp. (spores) 5,200 Oospora lactis 11,000
B. paratyphosus 6,100 Penicillium expansum 22,000
B. subtilis 11,000
B. subtilis spores 22,000 PROTOZOA
Clostridium tetani 22,000 Chlorella vulgaris (algae) 22,000
Corynebacterium diphtheria 6,500
Dysentery baccili 4,200 VIRUSES
Eberthella typhosa 4,100 Bacteriophage (E. coli) 6,600
Escherichia coli 6,600 Hepatitus virus 8,000
Leptospira 6,000 Influenza virus 6,600
Micrococcus candidus
12,300 Polio virus 6,000
Micrococcus sphaeroides 15,400
Mycobacterium tuberculosis 10,000 YEAST
Neisseria catarrhalis 8,500 Bakers' yeast 8,800
Phytomonas tumefaciens 8,500 Brewers' yeast 6,600
Proteus vulgaris 6,600 Common yeast cake 13,200
Pseudomonas aeruginosa 10,500 Saccharomyces cerevisiae 13,200
Pseudomonas fluorescens 6,600 Saccharomyces ellipsoideus 13,200
Salmonella 10,000 Saccharomyces sp. 17,600
S. enteritidis 7,600
S. typhimurium 15,200
S. typhosa 4,100
Sarcina lutea 26,400
Serratia marcescens 6,160
Shigella dysenteriae 4,200
Shigella paradysenteriae 3,400
Spirillum rubrum 6,160
Staphylococcus albus 5,720
Staphylococcus aureus 6,600
Streptococcus hemolyticus 5,500
Streptococcus viridans 3,800

 

GENERAL INSTALLATION AND SERVICE PARAMETERS

The BioMaster™ has been designed to give many years of trouble-free service. To keep the system operating at peak efficiency, expect to replace the sediment pre-filter every six months. The remainder of the system should be serviced on an annual basis, replacing all of the carbon filters, the RO module*, and the UV lamp. XX

* The BioMaster RO module may last for a much longer period of time on relatively good water. The included dual -channel TDS meter will help determine the membrane's status.

 

The BioMaster™ System will work at peak efficiency on either municipal or ground water supplies that do not exceed the following parameters:

Maximum psi
TDS
Iron
Hardness
Hydrogen Sulfide
Manganese
125 lbs.
1800 ppm
0.4 ppm
17 gr/gal
0.05 ppm
0.1 ppm